IDT7026S/L
High-Speed 16K x 16 Dual-Port Static RAM
Military, Industrial and Commercial Temperature Ranges
AC Electrical Characteristics Over the
Operating Temperature and Supply Voltage Range (4)
7026X15
Com'l Only
7026X20
Com'l, Ind
& Military
7026X25
Com'l, Ind
& Military
Symbol
Parameter
Min.
Max.
Min.
Max.
Min.
Max.
Unit
READ CYCLE
t RC
t AA
Read Cycle Time
Address Access Time
15
____
____
15
20
____
____
20
25
____
____
25
ns
ns
t ACE
Chip Enable Access Time
(3)
____
15
____
20
____
25
ns
t ABE
t AOE
t OH
Byte Enable Access Time (3)
Output Enable Access Time
Output Hold from Address Change
____
____
3
15
10
____
____
____
3
20
12
____
____
____
3
25
13
____
ns
ns
ns
t LZ
Output Low-Z Time
(1,2)
3
____
3
____
3
____
ns
t HZ
t PU
Output High-Z Time (1,2)
Chip Enable to Power Up Time (2)
____
0
10
____
____
0
12
____
____
0
15
____
ns
ns
t PD
Chip Disable to Power Down Time
(2)
____
15
____
20
____
25
ns
t SOP
t SAA
Semaphore Flag Update Pulse ( OE or SEM )
Semaphore Address Access Time
10
____
____
15
10
____
____
20
12
____
____
25
ns
ns
2939 tbl 12a
7026X35
Com'l, Ind
& Military
7026X55
Com'l, Ind
& Military
Symbol
Parameter
Min.
Max.
Min.
Max.
Unit
READ CYCLE
t RC
t AA
Read Cycle Time
Address Access Time
35
____
____
35
55
____
____
55
ns
ns
t ACE
t ABE
Chip Enable Access Time
Byte Enable Access Time
(3)
(3)
____
____
35
35
____
____
55
55
ns
ns
t AOE
t OH
Output Enable Access Time
Output Hold from Address Change
____
3
20
____
____
3
30
____
ns
ns
t LZ
Output Low-Z Time
(1,2)
3
____
3
____
ns
t HZ
Output High-Z Time
(1,2)
____
15
____
25
ns
t PU
t PD
t SOP
t SAA
Chip Enable to Power Up Time (2)
Chip Disable to Power Down Time (2)
Semaphore Flag Update Pulse ( OE or SEM )
Semaphore Address Access Time
0
____
15
____
____
35
____
35
0
____
15
____
____
50
____
55
ns
ns
ns
ns
NOTES:
1. Transition is measured 0mV from Low or High-impedance voltage with Output Test Load (Figure 2).
2. This parameter is guaranteed by device characterization, but is not production tested.
3. To access RAM, CE = V IL and SEM = V IH . To access semaphore, CE = V IH and SEM = V IL .
4. 'X' in part numbers indicates power rating (S or L).
7
6.42
2939 tbl 12b